245 | 1 | 0 |
_aBiomechanics in Dentistry: Evaluation of Different Surgical Approaches to Treat Atrophic Maxilla Patients _h[electronic resource] / _cby Muhammad Ikman Ishak, Mohammed Rafiq Abdul Kadir. |
264 | 1 |
_aBerlin, Heidelberg : _bSpringer Berlin Heidelberg : _bImprint: Springer, _c2013. |
|
300 |
_aXIII, 91 p. 72 illus. _bonline resource. |
||
336 |
_atext _btxt _2rdacontent |
||
337 |
_acomputer _bc _2rdamedia |
||
338 |
_aonline resource _bcr _2rdacarrier |
||
347 |
_atext file _bPDF _2rda |
||
490 | 1 |
_aSpringerBriefs in Applied Sciences and Technology, _x2191-530X |
|
505 | 0 | _aAnatomical Considerations -- Treatment Options for Severely Atrophic Maxillae -- Biomechanical Considerations -- Finite Element Modelling -- Bone and Prosthetic Component Responses in Various Occlusal Loading Locations -- Bone and Prosthetic Component Responses in Various Occlusal Loading Directions. | |
520 | _aThis book shows computational finite element simulations to analyse the strength of implant anchorage for intrasinus and extramaxillary approaches under various occlusal loading locations and directions. Three-dimensional model of the craniofacial area surrounding the region of interest, soft tissue and framework are developed using computed tomography image datasets. The zygomatic and standard dental implants are modeled using a conventional computer-aided design software and placed at the appropriate location. Material properties are assigned appropriately for the cortical, cancellous bones and implants with Masseter forces applied at the zygomatic arch and occlusal loadings applied on the framework surface. | ||
650 | 0 | _aEngineering. | |
650 | 0 | _aDentistry. | |
650 | 0 | _aMaterials. | |
650 | 0 | _aBiomedical engineering. | |
650 | 0 | _aBiomaterials. | |
650 | 1 | 4 | _aEngineering. |
650 | 2 | 4 | _aBiomedical Engineering. |
650 | 2 | 4 | _aBiomaterials. |
650 | 2 | 4 | _aContinuum Mechanics and Mechanics of Materials. |
650 | 2 | 4 | _aDentistry. |
700 | 1 |
_aAbdul Kadir, Mohammed Rafiq. _eauthor. |
|
710 | 2 | _aSpringerLink (Online service) | |
773 | 0 | _tSpringer eBooks | |
776 | 0 | 8 |
_iPrinted edition: _z9783642326028 |
830 | 0 |
_aSpringerBriefs in Applied Sciences and Technology, _x2191-530X |
|
856 | 4 | 0 | _uhttp://dx.doi.org/10.1007/978-3-642-32603-5 |
912 | _aZDB-2-ENG | ||
950 | _aEngineering (Springer-11647) | ||
999 |
_c24143 _d24143 |